- Single universal input
- Digital accuracy up to 0.14°C for RTD
- Easy-to-use-and-read basic display
- Transmitter and sensor diagnostics
- HART7 communications
- Full compliance with SIL 2/3 requirements
- Up to a 3-year warranty
- FM/CSA/ATEX/IECEx approvals.
Software & Interface
- Display
- Modular LCD, 2 lines, 6 digits, Field Configurable, Multiple Units ( deg C, deg F, deg R, Kelvin, mV, Ohm)
Environmental Conditions
- Ambient Temperature Range
- -40 to +85 deg C (-40 to +185 deg F) Rated, -55 to +120 deg C (-67 to +248 deg F) Storage
- Relative Humidity
- 0 to 100% RH (Non-Condensing)
- Load Resistance
- 0 to 1400 Ω (HART)
- Stability
- ±0.01% of URL/year for 10 years
I/O Capabilities
- Galvanic Isolation
- 2000 VDC (1400 Vrms)
- Configuration
- Integral Three-Button, Handheld (Versatilis, HART), PC (Field Device Manager, FDM Express)
- Update Time
- 125 ms (Single Input), 250 ms (Dual Input)
Electrical Specifications
- Supply Voltage
- 11.8 to 42.4 VDC (IS versions limited to 30 VDC)
- Output Options
- 4 to 20 mA DC, HART® (v7.0)
- Input Type
- RTD (2, 3, 4 wire), Thermocouple, Millivolt, Ohm voltage direct current
Material Specifications
- Materials
- Aluminum (Polyester Powder-Coated, Low Copper), Optional 316 Stainless Steel, Silicone O-Ring
Mechanical & Physical Properties
- Enclosure
- IP66, IP67 (NEMA 4X)
Standards & Certifications
- Approvals
- Safety: IEC 61508 SIL 2/3, EMC: (EN 61326-1, EN 61326-3-1), Marine: (ABS, DNV, LR, BV), Explosion Proof and Intrinsic Safety: (FM, CSA, ATEX, IECEx, NEPSI, KOSHA, INMETRO, SAEx, EAC, CCoE)
Applications & Compatibility
- Mounting
- Wall, Pipe, DIN Rail, Direct Sensor Head
Processing & Performance Metrics
- Accuracy
- Digital: up to ±0.14 deg C; Output D/A: ±0.025% of span (Pt100)
Software & Interface
- Display
- Modular LCD, 2 lines, 6 digits, Field Configurable, Multiple Units ( deg C, deg F, deg R, Kelvin, mV, Ohm)
Environmental Conditions
- Ambient Temperature Range
- -40 to +85 deg C (-40 to +185 deg F) Rated, -55 to +120 deg C (-67 to +248 deg F) Storage
- Relative Humidity
- 0 to 100% RH (Non-Condensing)
- Load Resistance
- 0 to 1400 Ω (HART)
- Stability
- ±0.01% of URL/year for 10 years
I/O Capabilities
- Galvanic Isolation
- 2000 VDC (1400 Vrms)
- Configuration
- Integral Three-Button, Handheld (Versatilis, HART), PC (Field Device Manager, FDM Express)
- Update Time
- 125 ms (Single Input), 250 ms (Dual Input)
Electrical Specifications
- Supply Voltage
- 11.8 to 42.4 VDC (IS versions limited to 30 VDC)
- Output Options
- 4 to 20 mA DC, HART® (v7.0)
- Input Type
- RTD (2, 3, 4 wire), Thermocouple, Millivolt, Ohm voltage direct current
Material Specifications
- Materials
- Aluminum (Polyester Powder-Coated, Low Copper), Optional 316 Stainless Steel, Silicone O-Ring
Mechanical & Physical Properties
- Enclosure
- IP66, IP67 (NEMA 4X)
Standards & Certifications
- Approvals
- Safety: IEC 61508 SIL 2/3, EMC: (EN 61326-1, EN 61326-3-1), Marine: (ABS, DNV, LR, BV), Explosion Proof and Intrinsic Safety: (FM, CSA, ATEX, IECEx, NEPSI, KOSHA, INMETRO, SAEx, EAC, CCoE)
Applications & Compatibility
- Mounting
- Wall, Pipe, DIN Rail, Direct Sensor Head
Processing & Performance Metrics
- Accuracy
- Digital: up to ±0.14 deg C; Output D/A: ±0.025% of span (Pt100)
- Display : Modular LCD, 2 lines, 6 digits, Field Configurable, Multiple Units ( deg C, deg F, deg R, Kelvin, mV, Ohm)
- Ambient Temperature Range : -40 to +85 deg C (-40 to +185 deg F) Rated, -55 to +120 deg C (-67 to +248 deg F) Storage
- Galvanic Isolation : 2000 VDC (1400 Vrms)
- Relative Humidity : 0 to 100% RH (Non-Condensing)
- Load Resistance : 0 to 1400 Ω (HART)
- Supply Voltage : 11.8 to 42.4 VDC (IS versions limited to 30 VDC)
- Output Options : 4 to 20 mA DC, HART® (v7.0)
- Configuration : Integral Three-Button, Handheld (Versatilis, HART), PC (Field Device Manager, FDM Express)
- Update Time : 125 ms (Single Input), 250 ms (Dual Input)
- Input Type : RTD (2, 3, 4 wire), Thermocouple, Millivolt, Ohm voltage direct current
- Stability : ±0.01% of URL/year for 10 years
- Materials : Aluminum (Polyester Powder-Coated, Low Copper), Optional 316 Stainless Steel, Silicone O-Ring
- Enclosure : IP66, IP67 (NEMA 4X)
- Approvals : Safety: IEC 61508 SIL 2/3, EMC: (EN 61326-1, EN 61326-3-1), Marine: (ABS, DNV, LR, BV), Explosion Proof and Intrinsic Safety: (FM, CSA, ATEX, IECEx, NEPSI, KOSHA, INMETRO, SAEx, EAC, CCoE)
- Mounting : Wall, Pipe, DIN Rail, Direct Sensor Head
- Accuracy : Digital: up to ±0.14 deg C; Output D/A: ±0.025% of span (Pt100)