enraf tank gauging
Enraf Tank Temperature Measurement
Temperature gauging systems offer reliability, high measurement accuracy, minimal maintenance cost and easy installation for all types of liquid bulk terminals and storage facilities.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
What is It?
Honeywell’s Enraf® Tank Temperature Measurement portfolio ranges from single spot temperature probes to the advanced VITO Multiple Thermosensor Thermometers (MTT) for accurate temperature measurement. If required a water level probe can be integrated measuring the water level accurately at the bottom of the tank.
The VITO interface guarantees faultless communication with level gauges based on radar or servo technology.
Interfacing the tank gauge with the temperature measurement and even water level measurement reduces costs for wiring and installation.
How Does It Work?
Honeywell offers several types of temperature measurement instruments:
Spot Temperature Measurement is performed by probes directly connected to a level gauge and mounted at any desired location in the tank
Average Temperature Measurement is made possible by the VITO MRT which consists of multiple resistor elements, each with a different length. Depending on the liquid level measured by the level gauge, the longest element which is completely submerged in the liquid is selected to represent the average temperature of the stored product
Multiple Temperature Measurement is performed by the VITO LT which measures average product temperature and average gas temperature with a nine-element probe, while the VITO MTT goes a step further with a 16-element probe.
What Problems Does it Solve?
Honeywell's temperature measurement portfolio exceeds the requirements of all in-tank measurement standards. The top end temperature gauging systems – VITO LT and VITO MTT - are suitable for custody transfer purposes in conformity with weights and measures regulations. In addition, the VITO MTT is fit for LNG storage
VITO Interface
- Housing
- Chromatized, Polyurethane coated Aluminum, GD-AISi10Mg
- Data Communication
- HART® Communication to Tank Gauging ATG
- Application
- An electronic converter used in combination with the VITO probes
- Mounting
- Direct on VITO probes using standard 1/2 in BSP entry
Environmental Safety
- Storage Temperature Range
- LT/ MTT Probe: -55 to +135 deg C (-67 to +275 deg F)
- MPT Probe: -50 to +120 deg C
- Ambient Temperature Range
- -40 to +60 deg C (-40 to +140 deg F)
- Operating Pressure
- LT/MTT Probe: 5 bar/500 kPa (72 psi) Hydrostatic pressure
- MPT Probe: 6 bar/600 kPa (90 psi) hydrostatic pressure
- Safety Approvals
- LT/MTT Probe/ Interface Card: ATEX KEMA, IECEx, Kosha, FM, CSA , INMETRO TÜV
- MPT Probe : EN IEC 60079-11, clause 5.7
Measuring Specifications
- Probe Temperature Range
- LT/ MTT Probe: -55 to +135 deg C (-67 to +275 deg F)
- MPT Probe: -50 to +120 deg C
- Measuring Resolution
- 0.01 deg C
- Measuring Range
- ±2 mm (0.078 in)
- Probe Accuracy
- 1/10 DIN Class B = ± (0.12+0.0015·
- t
- ) deg C
- LT/ MTT Probe: ±0.1 deg C (±0.18 deg F)
- MPT Probe: 1/6 DIN Class B = ± (0.15+0.002·
- t
- ) deg C
Mechanical
- Probe Outer Diameter
- With Water Sensing - 40 mm (1.57 in)
- Without Water Sensing - LT Probe 27 mm (1.06 in), MPT Probe 28.6 mm (1.2 in)
- Sheath Material
- AISI 316L Stainless Steel
- Mounting Flange
- Optional, 1/2 BSP threaded mounting hole required
- Cable Entries
- M20 x 1.5, 3/4 in NPT via reducer and PG16 via reducer
- Anchor Weight
- Optional, max. 23 kg (50 lb)
Water Sensing-Optional
- Minimum Water Level
- 25 mm (0.98 in)
- Sensor Type
- PTFE sheathed capacitive probe
General
- Measuring Principle
- Cold junction compensated thermocouples (type T) to measure the temperature differentials with respect to a 4 wire 1/5 DIN Class A Pt100 reference resistor, physically embedded to cold junction
Principle
- Number of Elements
- LT Probe: 9 elements
- MTT Probe: 16 elements
Explosion Safety & Legal Metrology Approvals
- Ingress Protection
- IP66/IP67
VITO Interface
- Housing
- Chromatized, Polyurethane coated Aluminum, GD-AISi10Mg
- Data Communication
- HART® Communication to Tank Gauging ATG
- Application
- An electronic converter used in combination with the VITO probes
- Mounting
- Direct on VITO probes using standard 1/2 in BSP entry
Environmental Safety
- Storage Temperature Range
- LT/ MTT Probe: -55 to +135 deg C (-67 to +275 deg F)
- MPT Probe: -50 to +120 deg C
- Ambient Temperature Range
- -40 to +60 deg C (-40 to +140 deg F)
- Operating Pressure
- LT/MTT Probe: 5 bar/500 kPa (72 psi) Hydrostatic pressure
- MPT Probe: 6 bar/600 kPa (90 psi) hydrostatic pressure
- Safety Approvals
- LT/MTT Probe/ Interface Card: ATEX KEMA, IECEx, Kosha, FM, CSA , INMETRO TÜV
- MPT Probe : EN IEC 60079-11, clause 5.7
Measuring Specifications
- Probe Temperature Range
- LT/ MTT Probe: -55 to +135 deg C (-67 to +275 deg F)
- MPT Probe: -50 to +120 deg C
- Measuring Resolution
- 0.01 deg C
- Measuring Range
- ±2 mm (0.078 in)
- Probe Accuracy
- 1/10 DIN Class B = ± (0.12+0.0015·
- t
- ) deg C
- LT/ MTT Probe: ±0.1 deg C (±0.18 deg F)
- MPT Probe: 1/6 DIN Class B = ± (0.15+0.002·
- t
- ) deg C
Mechanical
- Probe Outer Diameter
- With Water Sensing - 40 mm (1.57 in)
- Without Water Sensing - LT Probe 27 mm (1.06 in), MPT Probe 28.6 mm (1.2 in)
- Sheath Material
- AISI 316L Stainless Steel
- Mounting Flange
- Optional, 1/2 BSP threaded mounting hole required
- Cable Entries
- M20 x 1.5, 3/4 in NPT via reducer and PG16 via reducer
- Anchor Weight
- Optional, max. 23 kg (50 lb)
Water Sensing-Optional
- Minimum Water Level
- 25 mm (0.98 in)
- Sensor Type
- PTFE sheathed capacitive probe
General
- Measuring Principle
- Cold junction compensated thermocouples (type T) to measure the temperature differentials with respect to a 4 wire 1/5 DIN Class A Pt100 reference resistor, physically embedded to cold junction
Principle
- Number of Elements
- LT Probe: 9 elements
- MTT Probe: 16 elements
Explosion Safety & Legal Metrology Approvals
- Ingress Protection
- IP66/IP67
- Housing : Chromatized, Polyurethane coated Aluminum, GD-AISi10Mg
- Storage Temperature Range : LT/ MTT Probe: -55 to +135 deg C (-67 to +275 deg F)|MPT Probe: -50 to +120 deg C
- Ambient Temperature Range : -40 to +60 deg C (-40 to +140 deg F)
- Probe Temperature Range : LT/ MTT Probe: -55 to +135 deg C (-67 to +275 deg F)|MPT Probe: -50 to +120 deg C
- Probe Outer Diameter : With Water Sensing - 40 mm (1.57 in)|Without Water Sensing - LT Probe 27 mm (1.06 in), MPT Probe 28.6 mm (1.2 in)
- Measuring Resolution : 0.01 deg C
- Minimum Water Level : 25 mm (0.98 in)
- Measuring Principle : Cold junction compensated thermocouples (type T) to measure the temperature differentials with respect to a 4 wire 1/5 DIN Class A Pt100 reference resistor, physically embedded to cold junction
- Operating Pressure : LT/MTT Probe: 5 bar/500 kPa (72 psi) Hydrostatic pressure|MPT Probe: 6 bar/600 kPa (90 psi) hydrostatic pressure
- Number of Elements : LT Probe: 9 elements|MTT Probe: 16 elements
- Ingress Protection : IP66/IP67
- Data Communication : HART® Communication to Tank Gauging ATG
- Safety Approvals : LT/MTT Probe/ Interface Card: ATEX KEMA, IECEx, Kosha, FM, CSA , INMETRO TÜV|MPT Probe : EN IEC 60079-11, clause 5.7
- Sheath Material : AISI 316L Stainless Steel
- Mounting Flange : Optional, 1/2 BSP threaded mounting hole required
- Measuring Range : ±2 mm (0.078 in)
- Probe Accuracy : 1/10 DIN Class B = ± (0.12+0.0015·|t|) deg C|LT/ MTT Probe: ±0.1 deg C (±0.18 deg F)|MPT Probe: 1/6 DIN Class B = ± (0.15+0.002·|t|) deg C
- Cable Entries : M20 x 1.5, 3/4 in NPT via reducer and PG16 via reducer
- Anchor Weight : Optional, max. 23 kg (50 lb)
- Sensor Type : PTFE sheathed capacitive probe
- Application : An electronic converter used in combination with the VITO probes
- Mounting : Direct on VITO probes using standard 1/2 in BSP entry
Brochure
Case Study
Filters