direct fired furnace burners
BIC..L
Excess air burners for all applications requiring precise temperature control and consistent product quality.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Features & Benefits:
- Capacity range: 75 kW to 440 kW
- Fuels: natural gas, LPG (gaseous), other types on request
- Direct spark ignition
- Max. furnace temperature is 4500°C
Environmental Conditions
- Ambient Temperature Range
- -20 to +180 deg C (-4 to +356 deg F)
Processing & Performance Metrics
- Turndown Capability
- High (supported by excess‑air operation)
- Outlet Velocity
- High (up to 250 m/s)
- Capacity Range
- 85 kW to 440 kW (320 to 1664 x 10³ BTU/h)
Maximum/Minimum Temperature Limits
- Maximum Furnace Temperature
- 1250 deg C (higher on request)
Combustion/Furnace/Chamber Temperatures
- Maximum Combustion Air Temperature
- ≤ 250 deg C
Electrical Specifications
- Maintenance Interval
- Twice per year (more frequent if media is contaminated)
Installation & Mounting Specifications
- Installation Orientation
- Horizontal or angled
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas
Ignition, Flame & Supervision Specifications
- Flame Supervision
- Flame rod standard
Burner/Flame‑Related Lengths
- Flame Length
- 450 to 900 mm depending on model
Air & Combustion Air Specifications
- Excess Air Capability
- Up to ≈1500% (λ up to ~16)
- Cooling/Purge Air Option
- 2 to 6 % of rated air flow when burner is off
Control, Logic & Functional Behavior
- Control Type
- On/Off, modulating
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Nozzle‑mixing (gas and air mix only at burner head)
Standards & Certifications
- Approvals
- EN 746-2 (Compliance for industrial thermoprocessing equipment), Eurasian Customs Union (Meets technical specifications), Machinery Directive 2006/42/EC Declaration of Incorporation confirmed, WEEE Directive Disposal compliance
Environmental Conditions
- Ambient Temperature Range
- -20 to +180 deg C (-4 to +356 deg F)
Processing & Performance Metrics
- Turndown Capability
- High (supported by excess‑air operation)
- Outlet Velocity
- High (up to 250 m/s)
- Capacity Range
- 85 kW to 440 kW (320 to 1664 x 10³ BTU/h)
Maximum/Minimum Temperature Limits
- Maximum Furnace Temperature
- 1250 deg C (higher on request)
Combustion/Furnace/Chamber Temperatures
- Maximum Combustion Air Temperature
- ≤ 250 deg C
Electrical Specifications
- Maintenance Interval
- Twice per year (more frequent if media is contaminated)
Installation & Mounting Specifications
- Installation Orientation
- Horizontal or angled
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas
Ignition, Flame & Supervision Specifications
- Flame Supervision
- Flame rod standard
Burner/Flame‑Related Lengths
- Flame Length
- 450 to 900 mm depending on model
Air & Combustion Air Specifications
- Excess Air Capability
- Up to ≈1500% (λ up to ~16)
- Cooling/Purge Air Option
- 2 to 6 % of rated air flow when burner is off
Control, Logic & Functional Behavior
- Control Type
- On/Off, modulating
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Nozzle‑mixing (gas and air mix only at burner head)
Standards & Certifications
- Approvals
- EN 746-2 (Compliance for industrial thermoprocessing equipment), Eurasian Customs Union (Meets technical specifications), Machinery Directive 2006/42/EC Declaration of Incorporation confirmed, WEEE Directive Disposal compliance
- Ambient Temperature Range : -20 to +180 deg C (-4 to +356 deg F)
- Turndown Capability : High (supported by excess‑air operation)
- Outlet Velocity : High (up to 250 m/s)
- Maximum Furnace Temperature : 1250 deg C (higher on request)
- Maximum Combustion Air Temperature : ≤ 250 deg C
- Maintenance Interval : Twice per year (more frequent if media is contaminated)
- Installation Orientation : Horizontal or angled
- Fuel Type : Natural Gas
- Flame Supervision : Flame rod standard
- Flame Length : 450 to 900 mm depending on model
- Excess Air Capability : Up to ≈1500% (λ up to ~16)
- Cooling/Purge Air Option : 2 to 6 % of rated air flow when burner is off
- Control Type : On/Off, modulating
- Combustion Principle : Nozzle‑mixing (gas and air mix only at burner head)
- Capacity Range : 85 kW to 440 kW (320 to 1664 x 10³ BTU/h)
- Approvals : EN 746-2 (Compliance for industrial thermoprocessing equipment), Eurasian Customs Union (Meets technical specifications), Machinery Directive 2006/42/EC Declaration of Incorporation confirmed, WEEE Directive Disposal compliance
Please sign in to view part numbers available for purchase based on your account Sign In