  • Capacity range: 75 kW to 440 kW
  • Fuels: natural gas, LPG (gaseous), other types on request
  • Direct spark ignition
  • Max. furnace temperature is 4500°C
More Information:
Specifications

Environmental Conditions

  • Ambient Temperature Range
    • -20 to +180 deg C (-4 to +356 deg F)

Processing & Performance Metrics

  • Turndown Capability
    • High (supported by excess‑air operation)
  • Outlet Velocity
    • High (up to 250 m/s)
  • Capacity Range
    • 85 kW to 440 kW (320 to 1664 x 10³ BTU/h)

Maximum/Minimum Temperature Limits

  • Maximum Furnace Temperature
    • 1250 deg C (higher on request)

Combustion/Furnace/Chamber Temperatures

  • Maximum Combustion Air Temperature
    • ≤ 250 deg C

Electrical Specifications

  • Maintenance Interval
    • Twice per year (more frequent if media is contaminated)

Installation & Mounting Specifications

  • Installation Orientation
    • Horizontal or angled

Fuel, Gas & Media Specifications

  • Fuel Type
    • Natural Gas

Ignition, Flame & Supervision Specifications

  • Flame Supervision
    • Flame rod standard

Burner/Flame‑Related Lengths

  • Flame Length
    • 450 to 900 mm depending on model

Air & Combustion Air Specifications

  • Excess Air Capability
    • Up to ≈1500% (λ up to ~16)
  • Cooling/Purge Air Option
    • 2 to 6 % of rated air flow when burner is off

Control, Logic & Functional Behavior

  • Control Type
    • On/Off, modulating

Combustion, Mixing & Fuel Dynamics

  • Combustion Principle
    • Nozzle‑mixing (gas and air mix only at burner head)

Standards & Certifications

  • Approvals
    • EN 746-2 (Compliance for industrial thermoprocessing equipment), Eurasian Customs Union (Meets technical specifications), Machinery Directive 2006/42/EC Declaration of Incorporation confirmed, WEEE Directive Disposal compliance

Environmental Conditions

  • Ambient Temperature Range
    • -20 to +180 deg C (-4 to +356 deg F)

Processing & Performance Metrics

  • Turndown Capability
    • High (supported by excess‑air operation)
  • Outlet Velocity
    • High (up to 250 m/s)
  • Capacity Range
    • 85 kW to 440 kW (320 to 1664 x 10³ BTU/h)

Maximum/Minimum Temperature Limits

  • Maximum Furnace Temperature
    • 1250 deg C (higher on request)

Combustion/Furnace/Chamber Temperatures

  • Maximum Combustion Air Temperature
    • ≤ 250 deg C

Electrical Specifications

  • Maintenance Interval
    • Twice per year (more frequent if media is contaminated)

Installation & Mounting Specifications

  • Installation Orientation
    • Horizontal or angled

Fuel, Gas & Media Specifications

  • Fuel Type
    • Natural Gas

Ignition, Flame & Supervision Specifications

  • Flame Supervision
    • Flame rod standard

Burner/Flame‑Related Lengths

  • Flame Length
    • 450 to 900 mm depending on model

Air & Combustion Air Specifications

  • Excess Air Capability
    • Up to ≈1500% (λ up to ~16)
  • Cooling/Purge Air Option
    • 2 to 6 % of rated air flow when burner is off

Control, Logic & Functional Behavior

  • Control Type
    • On/Off, modulating

Combustion, Mixing & Fuel Dynamics

  • Combustion Principle
    • Nozzle‑mixing (gas and air mix only at burner head)

Standards & Certifications

  • Approvals
    • EN 746-2 (Compliance for industrial thermoprocessing equipment), Eurasian Customs Union (Meets technical specifications), Machinery Directive 2006/42/EC Declaration of Incorporation confirmed, WEEE Directive Disposal compliance
  • Ambient Temperature Range : -20 to +180 deg C (-4 to +356 deg F)
  • Turndown Capability : High (supported by excess‑air operation)
  • Outlet Velocity : High (up to 250 m/s)
  • Maximum Furnace Temperature : 1250 deg C (higher on request)
  • Maximum Combustion Air Temperature : ≤ 250 deg C
  • Maintenance Interval : Twice per year (more frequent if media is contaminated)
  • Installation Orientation : Horizontal or angled
  • Fuel Type : Natural Gas
  • Flame Supervision : Flame rod standard
  • Flame Length : 450 to 900 mm depending on model
  • Excess Air Capability : Up to ≈1500% (λ up to ~16)
  • Cooling/Purge Air Option : 2 to 6 % of rated air flow when burner is off
  • Control Type : On/Off, modulating
  • Combustion Principle : Nozzle‑mixing (gas and air mix only at burner head)
  • Capacity Range : 85 kW to 440 kW (320 to 1664 x 10³ BTU/h)
  • Approvals : EN 746-2 (Compliance for industrial thermoprocessing equipment), Eurasian Customs Union (Meets technical specifications), Machinery Directive 2006/42/EC Declaration of Incorporation confirmed, WEEE Directive Disposal compliance