line and duct burners
RatioStar
Duct Burner with Stable flame and high performance.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Typical Applications:
- Air heating processes that require optimum heat distribution in process air flows
- Air heating processes that require optimum combustion efficiency(on-ratio control)
- Low oxygen process air flows that require additional heat
- Process air flows with high inlet temperatures up to 1400ºF (750ºC), where standard air heating burners cannot be used
- Processes that require low emissions of CO, NOx and unburned hydrocarbons
Air & Combustion Air Specifications
- Air Inlet Pressure
- ± 10 to 15 mbar
- Air Pressure Drop
- 2 to 2.5 mbar across stabilization plate
Processing & Performance Metrics
- Velocity Across Burner
- Advised ≈10-15 m/s; Range ≈5-25 m/s
- Emissions
- CO and NOx performance shown in datasheet graphs (application‑dependent)
Combustion Air, Blower & Emissions Specifications
- Typical Excess Air
- ≈30% (λ ≈ 1.3 at maximum input)
Performance, Flow & Capacity
- Turndown Ratio
- 1:5 on air
Temperature Control/Measurement
- Temperature Limits
- Upstream: 1110 deg F (600 deg C), Downstream: 1830 deg F (1000 deg C)
Pressure Specifications
- Nozzle Gas Pressure
- Natural Gas 59 mbar; Propane 25 mbar
Overview
- Model Name
- RatioStar RAS, Version 1
Performance Specifications
- Input Capacity
- Max - 425,000 Btu/h (125 kW) per module
- Min - 42,500 Btu/h (12.5 kW) per module
Ignition, Flame & Supervision Specifications
- Ignition Type
- Pilot
- Flame Supervision
- UV Scanner only
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas; Propane (other gases on request)
Burner/Flame‑Related Lengths
- Flame Length
- ≈1500 mm from Stabilization Plate
Dimensions & Weight
- Dimensions
- ≈150 x 150 mm
Control, Logic & Functional Behavior
- Control Method
- Mechanically or electronically linked air/gas valves
Standards & Certifications
- Approvals
- Gas Manifold: AISI 316L (1.4404); Stabilization Plate: Avesta 253 MA (1.4893); Flame Shield: Avesta 253 MA (1.4893); Gas Nozzles: AISI 321 (1.4541)
Air & Combustion Air Specifications
- Air Inlet Pressure
- ± 10 to 15 mbar
- Air Pressure Drop
- 2 to 2.5 mbar across stabilization plate
Processing & Performance Metrics
- Velocity Across Burner
- Advised ≈10-15 m/s; Range ≈5-25 m/s
- Emissions
- CO and NOx performance shown in datasheet graphs (application‑dependent)
Combustion Air, Blower & Emissions Specifications
- Typical Excess Air
- ≈30% (λ ≈ 1.3 at maximum input)
Performance, Flow & Capacity
- Turndown Ratio
- 1:5 on air
Temperature Control/Measurement
- Temperature Limits
- Upstream: 1110 deg F (600 deg C), Downstream: 1830 deg F (1000 deg C)
Pressure Specifications
- Nozzle Gas Pressure
- Natural Gas 59 mbar; Propane 25 mbar
Overview
- Model Name
- RatioStar RAS, Version 1
Performance Specifications
- Input Capacity
- Max - 425,000 Btu/h (125 kW) per module
- Min - 42,500 Btu/h (12.5 kW) per module
Ignition, Flame & Supervision Specifications
- Ignition Type
- Pilot
- Flame Supervision
- UV Scanner only
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas; Propane (other gases on request)
Burner/Flame‑Related Lengths
- Flame Length
- ≈1500 mm from Stabilization Plate
Dimensions & Weight
- Dimensions
- ≈150 x 150 mm
Control, Logic & Functional Behavior
- Control Method
- Mechanically or electronically linked air/gas valves
Standards & Certifications
- Approvals
- Gas Manifold: AISI 316L (1.4404); Stabilization Plate: Avesta 253 MA (1.4893); Flame Shield: Avesta 253 MA (1.4893); Gas Nozzles: AISI 321 (1.4541)
- Air Inlet Pressure : ± 10 to 15 mbar
- Velocity Across Burner : Advised ≈10-15 m/s; Range ≈5-25 m/s
- Typical Excess Air : ≈30% (λ ≈ 1.3 at maximum input)
- Turndown Ratio : 1:5 on air
- Temperature Limits : Upstream: 1110 deg F (600 deg C), Downstream: 1830 deg F (1000 deg C)
- Nozzle Gas Pressure : Natural Gas 59 mbar; Propane 25 mbar
- Model Name : RatioStar RAS, Version 1
- Input Capacity : Max - 425,000 Btu/h (125 kW) per module|Min - 42,500 Btu/h (12.5 kW) per module
- Ignition Type : Pilot
- Fuel Type : Natural Gas; Propane (other gases on request)
- Flame Supervision : UV Scanner only
- Flame Length : ≈1500 mm from Stabilization Plate
- Emissions : CO and NOx performance shown in datasheet graphs (application‑dependent)
- Dimensions : ≈150 x 150 mm
- Control Method : Mechanically or electronically linked air/gas valves
- Approvals : Gas Manifold: AISI 316L (1.4404); Stabilization Plate: Avesta 253 MA (1.4893); Flame Shield: Avesta 253 MA (1.4893); Gas Nozzles: AISI 321 (1.4541)
- Air Pressure Drop : 2 to 2.5 mbar across stabilization plate
Filters
Please sign in to view part numbers available for purchase based on your account Sign In