/content/process/us/en/search.html

turbine and quantometers

Q75 - Quantometer

Short pattern turbine gas meter for pipes up to DN 750 / 30

Overview
The high performance is subscribed by the fact that the Q75 series is approved for fiscal metering in a number of countries. The series offers a large variety, from cast body to spool piece, sizes up to DN 750 / 30, and a multitude of options, from lubrication systems to high frequency output.
Specifications

Processing & Performance Metrics

  • Accuracy
    • ±1.5% from 0.2 Qmax to Qmax
    • ±3.0% from Qmin to 0.2 Qmax

Technical Specifications

  • Flange Connections
    • EN or ASME standards
  • Suitable Media
    • Natural Gas, Air, Methane, Nitrogen, Other Non-Corrosive Gases
  • Pulse Output
    • 2x Low Frequency (LF) Standard, High Frequency (HF) Optional
  • Design Type
    • Flanged or Sandwich

Environmental Conditions

  • Temperature Range
    • -10 to +60 deg C (others on request)
  • Measuring Range
    • Up to 1:20

Standards & Certifications

  • Protection Class
    • IP67 (Suitable for Outdoor Installation)

Overview

  • Index Variants
    • MI-2

Software & Interface

  • Index Display
    • 8-Digit Mechanical Roller Counter

Material Specifications

  • Body Material
    • Cast Iron or Steel

Applications & Compatibility

  • Applications
    • Consumption monitoring for burners, boilers, furnaces
    • In-plant allocation metering
    • Volume input for controls
  • Mounting
    • Horizontal Only

Mechanical & Physical Properties

  • Meter Sizes
    • DN 200 to DN 600 (8 to 24 in)

I/O Capabilities

  • LF Pulsers
    • IN-S10 (Standard), IN-S11/IN-S12 (Optional)
  • HF Pulsers
    • BI-ISM-Y1 Type

Industries / Applications & Compatibility

  • Industries
    • Heavy Industry, Petrochemicals, Steel, Power, Minerals, Heating

Electrical Specifications

  • Flow Rate
    • 6 to 25,000 m³/h

Processing & Performance Metrics

  • Accuracy
    • ±1.5% from 0.2 Qmax to Qmax
    • ±3.0% from Qmin to 0.2 Qmax

Technical Specifications

  • Flange Connections
    • EN or ASME standards
  • Suitable Media
    • Natural Gas, Air, Methane, Nitrogen, Other Non-Corrosive Gases
  • Pulse Output
    • 2x Low Frequency (LF) Standard, High Frequency (HF) Optional
  • Design Type
    • Flanged or Sandwich

Environmental Conditions

  • Temperature Range
    • -10 to +60 deg C (others on request)
  • Measuring Range
    • Up to 1:20

Standards & Certifications

  • Protection Class
    • IP67 (Suitable for Outdoor Installation)

Overview

  • Index Variants
    • MI-2

Software & Interface

  • Index Display
    • 8-Digit Mechanical Roller Counter

Material Specifications

  • Body Material
    • Cast Iron or Steel

Applications & Compatibility

  • Applications
    • Consumption monitoring for burners, boilers, furnaces
    • In-plant allocation metering
    • Volume input for controls
  • Mounting
    • Horizontal Only

Mechanical & Physical Properties

  • Meter Sizes
    • DN 200 to DN 600 (8 to 24 in)

I/O Capabilities

  • LF Pulsers
    • IN-S10 (Standard), IN-S11/IN-S12 (Optional)
  • HF Pulsers
    • BI-ISM-Y1 Type

Industries / Applications & Compatibility

  • Industries
    • Heavy Industry, Petrochemicals, Steel, Power, Minerals, Heating

Electrical Specifications

  • Flow Rate
    • 6 to 25,000 m³/h
  • Accuracy : ±1.5% from 0.2 Qmax to Qmax|±3.0% from Qmin to 0.2 Qmax
  • Flange Connections : EN or ASME standards
  • Temperature Range : -10 to +60 deg C (others on request)
  • Protection Class : IP67 (Suitable for Outdoor Installation)
  • Measuring Range : Up to 1:20
  • Suitable Media : Natural Gas, Air, Methane, Nitrogen, Other Non-Corrosive Gases
  • Index Variants : MI-2
  • Index Display : 8-Digit Mechanical Roller Counter
  • Body Material : Cast Iron or Steel
  • Pulse Output : 2x Low Frequency (LF) Standard, High Frequency (HF) Optional
  • Applications : Consumption monitoring for burners, boilers, furnaces|In-plant allocation metering|Volume input for controls
  • Meter Sizes : DN 200 to DN 600 (8 to 24 in)
  • Design Type : Flanged or Sandwich
  • LF Pulsers : IN-S10 (Standard), IN-S11/IN-S12 (Optional)
  • Industries : Heavy Industry, Petrochemicals, Steel, Power, Minerals, Heating
  • HF Pulsers : BI-ISM-Y1 Type
  • Flow Rate : 6 to 25,000 m³/h
  • Mounting : Horizontal Only
Data Sheet
Name
Description
File Size
Date
Size
Datasheet for Elster Turbine gas meters for secondary metering in the heavy industrial and commercial space. Not approved for fiscal measurement. Used for in-plant allocation, process monitoring and control.
application/pdf 156.38 KB
11/11/2021
156.38 KB
Name
Description
File Size
Date
Size
Datasheet for Elster Turbine gas meters for secondary metering in the heavy industrial and commercial space. Not approved for fiscal measurement. Used for in-plant allocation, process monitoring and control.
application/pdf 156.38 KB
11/11/2021
156.38 KB
Name
Description
File Size
Date
Size
Datasheet for Elster Turbine gas meters for secondary metering in the heavy industrial and commercial space. Not approved for fiscal measurement. Used for in-plant allocation, process monitoring and control.
156.38 KB
11/11/2021
Name
Description
File Size
Date
Size
No support documents tagged to this product
An error occurred . Please try after sometime
Part Number
Description
Leaf Category
Thumbnail
Add to list