Blast Tips are suitable for variety of applications. In general, Blast Tips are built to burn without the use of any refractory tunnel and are either self-piloting or built to prevent the flame from blowing away under normal conditions of operation. Due to the marked differences in combustion characteristics of various combustible gases, it is not always possible to use the same tip on all gases. A tip that may have good flame retention when burning coke oven gas may not hold a natural gas flame at all. They can be used in groups to heat a wide area such as the bottom of a kettle, or mounted down a length of pipe as in a core oven.
Specifications

Processing & Performance Metrics

  • Capacity Range
    • Ferrofix - 6,090 to 5,700,000 BTU/hr (HHV) at 6 in. wc
    • Sticktite - 37,000 to 5,250,000 BTU/hr (HHV) at 6 in. wc

Applications & Compatibility

  • Typical Uses
    • Boilers, kilns, ovens, air heaters, furnaces, immersion heating
  • Compatible Mixers
    • Injectors (low/high pressure), proportional mixers, Variset® mixers

Dimensions & Size Specifications

  • Sizes
    • Ferrofix - 1/4 to 6 in pipe sizes
    • Sticktite - 1/2 to 6 in pipe sizes

Combustion, Fuel & Mixing Sub‑Systems

  • Nozzle Type
    • Open‑type, flame‑retention design
  • Nozzle Series
    • Ferrofix, Sticktite

Pressure Specifications

  • Mixture Pressure
    • Rated at 6 in. wc (15 mbar)

Combustion, Mixing & Fuel Dynamics

  • Mixing Method
    • Used with air/gas mixing devices

Material Specifications

  • Material
    • Cast Iron, Steel

Fuel, Gas & Media Specifications

  • Gas Type
    • Natural Gas (0.6 specific gravity reference)

Ignition, Flame & Supervision Specifications

  • Flame Supervision
    • Suitable flame sensing and automatic fuel shutoff required

Combustion Design & Characteristics

  • Combustion Block
    • Not required; optional for refractory‑lined chambers

Processing & Performance Metrics

  • Capacity Range
    • Ferrofix - 6,090 to 5,700,000 BTU/hr (HHV) at 6 in. wc
    • Sticktite - 37,000 to 5,250,000 BTU/hr (HHV) at 6 in. wc

Applications & Compatibility

  • Typical Uses
    • Boilers, kilns, ovens, air heaters, furnaces, immersion heating
  • Compatible Mixers
    • Injectors (low/high pressure), proportional mixers, Variset® mixers

Dimensions & Size Specifications

  • Sizes
    • Ferrofix - 1/4 to 6 in pipe sizes
    • Sticktite - 1/2 to 6 in pipe sizes

Combustion, Fuel & Mixing Sub‑Systems

  • Nozzle Type
    • Open‑type, flame‑retention design
  • Nozzle Series
    • Ferrofix, Sticktite

Pressure Specifications

  • Mixture Pressure
    • Rated at 6 in. wc (15 mbar)

Combustion, Mixing & Fuel Dynamics

  • Mixing Method
    • Used with air/gas mixing devices

Material Specifications

  • Material
    • Cast Iron, Steel

Fuel, Gas & Media Specifications

  • Gas Type
    • Natural Gas (0.6 specific gravity reference)

Ignition, Flame & Supervision Specifications

  • Flame Supervision
    • Suitable flame sensing and automatic fuel shutoff required

Combustion Design & Characteristics

  • Combustion Block
    • Not required; optional for refractory‑lined chambers
  • Capacity Range : Ferrofix - 6,090 to 5,700,000 BTU/hr (HHV) at 6 in. wc|Sticktite - 37,000 to 5,250,000 BTU/hr (HHV) at 6 in. wc
  • Typical Uses : Boilers, kilns, ovens, air heaters, furnaces, immersion heating
  • Sizes : Ferrofix - 1/4 to 6 in pipe sizes|Sticktite - 1/2 to 6 in pipe sizes
  • Nozzle Type : Open‑type, flame‑retention design
  • Nozzle Series : Ferrofix, Sticktite
  • Mixture Pressure : Rated at 6 in. wc (15 mbar)
  • Mixing Method : Used with air/gas mixing devices
  • Material : Cast Iron, Steel
  • Gas Type : Natural Gas (0.6 specific gravity reference)
  • Flame Supervision : Suitable flame sensing and automatic fuel shutoff required
  • Compatible Mixers : Injectors (low/high pressure), proportional mixers, Variset® mixers
  • Combustion Block : Not required; optional for refractory‑lined chambers
Name
Description
File Size
Date
Size
No support documents tagged to this product
An error occurred . Please try after sometime
Category@category|Type@type

Filters

Product Number
Part Number
Description
Leaf Category
Thumbnail
Add to list
18902-1
NZL,STICKTITE,ST 102 10,0.5 IN.,NPT,STL
18902-1
NZL,STICKTITE,ST 102 10,0.5 IN.,NPT,STL
18902-2
NZL,STICKTITE,ST 102 A18 8 10,0.5 IN.,NP
18902-2
NZL,STICKTITE,ST 102 A18 8 10,0.5 IN.,NP
18903-1
NZL,STICKTITE,ST 103 14,0.75 IN.,NPT,STL
18903-1
NZL,STICKTITE,ST 103 14,0.75 IN.,NPT,STL