pre mix equipment
Eclipse Open Burner nozzles
Open burner nozzles for a wide variety of applications including boiler conversions, kilns, ovens, air heaters, furnaces, and immersion heating.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Applications & Compatibility
- Applications
- Boilers, kilns, ovens, air heaters, furnaces, immersion heating
Combustion, Mixing & Fuel Dynamics
- Typical Gas Basis
- Natural Gas, 0.6 specific gravity
Product Overview & Classification
- Product Name
- Eclipse Open Burner Nozzles
Dimensions & Size Specifications
- Pipe Size
- Ferrofix: 1/4 to 6 in
- Sticktite: 1/2 to 6 in
- Number of Sizes
- Ferrofix: 10 pipe sizes
- Sticktite: 10 pipe sizes
Combustion, Fuel & Mixing Sub‑Systems
- Nozzle Type
- Sticktite, Ferrofix
Material Specifications
- Material
- Ferrofix: Steel shell, optional heat‑resisting alloy
- Sticktite: Cast iron or heat‑resisting alloy
Ignition, Flame & Supervision Specifications
- Flame Type
- Built‑in flame retention feature
Burner/Flame‑Related Lengths
- Flame Length
- Ferrofix: Not explicitly specified
- Sticktite: 8 in to 10.5 feet (200 mm to 3.2 m)
Connections & Interfaces
- Connection Type
- Ferrofix: Male Threads
- Sticktite: Female Threads
Processing & Performance Metrics
- Capacity Range
- Ferrofix - 6,090 to 5,700,000 BTU/hr (2 to 1670 kW)
- Sticktite - 37,000 to 5,250,000 BTU/hr (11 to 1540 kW)
Overview
- Burner Type
- Open-type, flame‑retention nozzle
Applications & Compatibility
- Applications
- Boilers, kilns, ovens, air heaters, furnaces, immersion heating
Combustion, Mixing & Fuel Dynamics
- Typical Gas Basis
- Natural Gas, 0.6 specific gravity
Product Overview & Classification
- Product Name
- Eclipse Open Burner Nozzles
Dimensions & Size Specifications
- Pipe Size
- Ferrofix: 1/4 to 6 in
- Sticktite: 1/2 to 6 in
- Number of Sizes
- Ferrofix: 10 pipe sizes
- Sticktite: 10 pipe sizes
Combustion, Fuel & Mixing Sub‑Systems
- Nozzle Type
- Sticktite, Ferrofix
Material Specifications
- Material
- Ferrofix: Steel shell, optional heat‑resisting alloy
- Sticktite: Cast iron or heat‑resisting alloy
Ignition, Flame & Supervision Specifications
- Flame Type
- Built‑in flame retention feature
Burner/Flame‑Related Lengths
- Flame Length
- Ferrofix: Not explicitly specified
- Sticktite: 8 in to 10.5 feet (200 mm to 3.2 m)
Connections & Interfaces
- Connection Type
- Ferrofix: Male Threads
- Sticktite: Female Threads
Processing & Performance Metrics
- Capacity Range
- Ferrofix - 6,090 to 5,700,000 BTU/hr (2 to 1670 kW)
- Sticktite - 37,000 to 5,250,000 BTU/hr (11 to 1540 kW)
Overview
- Burner Type
- Open-type, flame‑retention nozzle
- Applications : Boilers, kilns, ovens, air heaters, furnaces, immersion heating
- Typical Gas Basis : Natural Gas, 0.6 specific gravity
- Product Name : Eclipse Open Burner Nozzles
- Pipe Size : Ferrofix: 1/4 to 6 in|Sticktite: 1/2 to 6 in
- Number of Sizes : Ferrofix: 10 pipe sizes|Sticktite: 10 pipe sizes
- Nozzle Type : Sticktite, Ferrofix
- Material : Ferrofix: Steel shell, optional heat‑resisting alloy|Sticktite: Cast iron or heat‑resisting alloy
- Flame Type : Built‑in flame retention feature
- Flame Length : Ferrofix: Not explicitly specified|Sticktite: 8 in to 10.5 feet (200 mm to 3.2 m)
- Connection Type : Ferrofix: Male Threads|Sticktite: Female Threads
- Capacity Range : Ferrofix - 6,090 to 5,700,000 BTU/hr (2 to 1670 kW)|Sticktite - 37,000 to 5,250,000 BTU/hr (11 to 1540 kW)
- Burner Type : Open-type, flame‑retention nozzle
Filters
Please sign in to view part numbers available for purchase based on your account Sign In