manual valves and filters
Adjustable Orifice Valves (ALO/ALO-R)
Precise gas flow adjustment.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Dimensions & Size Specifications
- Sizes
- 3/4, 1, 1‑1/4, 1‑1/2, 2 in
Performance, Flow & Capacity
- Flow Coefficient (Cv/Kvs)
- Cv values vary by size (e.g., ALO‑3: 4.70; ALO‑8: 24.81)
Pressure Specifications
- Maximum Inlet Pressure
- 40 psi (≈ 2.75 bar) millibar
Actuation, Valve & Motion Control Specifications
- Valve Body Pattern
- Globe‑Style Valve Body
- Orifice Design
- V‑port design for extremely fine ratio adjustment
Overview
- Product Type
- ALO - Straight‑through adjustable limiting orifice valve
- ALO-R - Right‑angle version of the adjustable limiting orifice valve
Applications & Compatibility
- Applications
- Nozzle‑mix burners, combustion systems requiring precise air/gas ratio control
Standards & Certifications
- Approvals
- Gas Appliances Directive (2009/142/EC), DIN 3586 - Thermally activated shut‑off devices for gas, Compliant with TRGI (DVGW Code of Practice G 600) and German Firing System Directive
Dimensions & Size Specifications
- Sizes
- 3/4, 1, 1‑1/4, 1‑1/2, 2 in
Performance, Flow & Capacity
- Flow Coefficient (Cv/Kvs)
- Cv values vary by size (e.g., ALO‑3: 4.70; ALO‑8: 24.81)
Pressure Specifications
- Maximum Inlet Pressure
- 40 psi (≈ 2.75 bar) millibar
Actuation, Valve & Motion Control Specifications
- Valve Body Pattern
- Globe‑Style Valve Body
- Orifice Design
- V‑port design for extremely fine ratio adjustment
Overview
- Product Type
- ALO - Straight‑through adjustable limiting orifice valve
- ALO-R - Right‑angle version of the adjustable limiting orifice valve
Applications & Compatibility
- Applications
- Nozzle‑mix burners, combustion systems requiring precise air/gas ratio control
Standards & Certifications
- Approvals
- Gas Appliances Directive (2009/142/EC), DIN 3586 - Thermally activated shut‑off devices for gas, Compliant with TRGI (DVGW Code of Practice G 600) and German Firing System Directive
- Sizes : 3/4, 1, 1‑1/4, 1‑1/2, 2 in
- Flow Coefficient (Cv/Kvs) : Cv values vary by size (e.g., ALO‑3: 4.70; ALO‑8: 24.81)
- Maximum Inlet Pressure : 40 psi (≈ 2.75 bar) millibar
- Valve Body Pattern : Globe‑Style Valve Body
- Orifice Design : V‑port design for extremely fine ratio adjustment
- Product Type : ALO - Straight‑through adjustable limiting orifice valve|ALO-R - Right‑angle version of the adjustable limiting orifice valve
- Applications : Nozzle‑mix burners, combustion systems requiring precise air/gas ratio control
- Approvals : Gas Appliances Directive (2009/142/EC), DIN 3586 - Thermally activated shut‑off devices for gas, Compliant with TRGI (DVGW Code of Practice G 600) and German Firing System Directive
Filters
Please sign in to view part numbers available for purchase based on your account Sign In