shutoff valves
V4944B, L, N/8944B, C, L, N Two-stage pressure regulating gas valves
V4944B, L, N/8944B, C, L, N are Two-stage Pressure Regulating Gas Valves. These valves are used on boilers, unit heaters, duct furnaces, makeup air and rooftop heaters.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Features & Benefits:
- Designed for replacement for V4844/V8844 Gas Valves
- Suitable for use on atmospheric boilers, commercial water heaters, and rooftop heaters
- V4944/V8944B, C, L, N models are solenoid-operated diaphragm valves that combine the functions of safety shutoff and pressure regulation in a single unit
- V4944/V8944B, N are for use with natural gas
- V4944/V8944C, L are for use with LP gas
- Valve body of die-cast aluminum with a straight-through pattern
- V4944 are used with line voltage, dual-stage controllers; V8944 are used with 24 Vac dual-stage thermostats or controllers
- Valve closes on power failure; recommended for final shutoff service
- Bleed Tapping: Two 5/16-24 UNF
- Pilot Tapping: 1/8-27 NPT
- Body Pattern: Straight-through, non-offset
- Valve Closing Time: 2 sec max
- Mounting: Upright (horizontal)
- Materials: Body – Aluminum
- Voltage: V4944-120 Vac; V8944-24 Vac
- Frequency: 60 Hz
- Power Consumption: V4944-9 VA max; V8944-12.4 VA max
- Electrical Connections: 1/4 in. (6 mm) spade terminals (quick connects), leadwires and cover for electrical conduit connection provided.
- Operating Temperature Range: -40°F to +150°F (-40°C to +66°C)
- Approvals, Underwriters Laboratories Inc.: File No. MH1639, Guide No. YIOZ (60 Hz only)
- Approvals, CSA: Certificate No. 158158-1042930, Guide No. 3302-01, 81 (Z21.21, Z21.78)
- Pressure Ratings (psi): 1/2 psi
- Pressure Ratings (kPa): 3.4 kPa
- Current Ratings: V4944-0.077 max amps at rated Vac/Hz; V8944-0.516 max amps at rated Vac/Hz
Overview
- Models
- V4944N1086, V4944N1094, V4944N1102
Environmental Conditions
- Ambient Temperature Range
- -40 to +150 deg F (-40 to +66 deg C)
Fluid/Media/Component Temperatures
- Fluid Temperature Range
- 150 deg F (66 deg C)
Connections & Interfaces
- Electrical Connections
- 1/4 in spade terminals
- Leadwires and conduit cover included
Electrical Specifications
- Maintenance Interval
- Periodic leak testing and regulator verification recommended
- Voltage Rating
- V4944: 120 VAC, 60 Hz (line‑voltage, dual‑stage control)
- V8944: 24 VAC (dual‑stage control)
Material Specifications
- Valve Body Material
- Die-Cast Aluminum
Processing & Performance Metrics
- Flow Capacity Range
- Approximately 400 kBtu/h to 5,000 kBtu/h, size and application dependent
Installation & Mounting Specifications
- Mounting Position
- Horizontal upright (electrical tower up); limited horizontal allowed
Actuation, Valve & Motion Control Specifications
- Valve Pattern
- Straight-through, non-offset
- Opening Time
- Rapid opening (<6 seconds)
- Closing Time
- Fast closing (≤2 seconds on power failure)
- Valve Type
- Two‑stage, solenoid‑operated diaphragm gas valves with pressure regulation
Applications & Compatibility
- Applications
- Boilers, unit heaters, duct furnaces, makeup‑air units, rooftop heaters, ovens, incinerators, and commercial/industrial burners
Dimensions & Size Specifications
- Pipe Size
- 1 in, 1-1/4 in, 1-1/2 in NPT
Standards & Certifications
- Approvals
- File MH1639, Guide YIOZ, ANSI Z21.21 Compliance Valve leak test and allowable leakage rates
Fuel, Gas & Media Specifications
- Gas Type
- Natural Gas, LPG
Overview
- Models
- V4944N1086, V4944N1094, V4944N1102
Environmental Conditions
- Ambient Temperature Range
- -40 to +150 deg F (-40 to +66 deg C)
Fluid/Media/Component Temperatures
- Fluid Temperature Range
- 150 deg F (66 deg C)
Connections & Interfaces
- Electrical Connections
- 1/4 in spade terminals
- Leadwires and conduit cover included
Electrical Specifications
- Maintenance Interval
- Periodic leak testing and regulator verification recommended
- Voltage Rating
- V4944: 120 VAC, 60 Hz (line‑voltage, dual‑stage control)
- V8944: 24 VAC (dual‑stage control)
Material Specifications
- Valve Body Material
- Die-Cast Aluminum
Processing & Performance Metrics
- Flow Capacity Range
- Approximately 400 kBtu/h to 5,000 kBtu/h, size and application dependent
Installation & Mounting Specifications
- Mounting Position
- Horizontal upright (electrical tower up); limited horizontal allowed
Actuation, Valve & Motion Control Specifications
- Valve Pattern
- Straight-through, non-offset
- Opening Time
- Rapid opening (<6 seconds)
- Closing Time
- Fast closing (≤2 seconds on power failure)
- Valve Type
- Two‑stage, solenoid‑operated diaphragm gas valves with pressure regulation
Applications & Compatibility
- Applications
- Boilers, unit heaters, duct furnaces, makeup‑air units, rooftop heaters, ovens, incinerators, and commercial/industrial burners
Dimensions & Size Specifications
- Pipe Size
- 1 in, 1-1/4 in, 1-1/2 in NPT
Standards & Certifications
- Approvals
- File MH1639, Guide YIOZ, ANSI Z21.21 Compliance Valve leak test and allowable leakage rates
Fuel, Gas & Media Specifications
- Gas Type
- Natural Gas, LPG
- Models : V4944N1086, V4944N1094, V4944N1102
- Ambient Temperature Range : -40 to +150 deg F (-40 to +66 deg C)
- Fluid Temperature Range : 150 deg F (66 deg C)
- Electrical Connections : 1/4 in spade terminals|Leadwires and conduit cover included
- Maintenance Interval : Periodic leak testing and regulator verification recommended
- Valve Body Material : Die-Cast Aluminum
- Flow Capacity Range : Approximately 400 kBtu/h to 5,000 kBtu/h, size and application dependent
- Mounting Position : Horizontal upright (electrical tower up); limited horizontal allowed
- Voltage Rating : V4944: 120 VAC, 60 Hz (line‑voltage, dual‑stage control)|V8944: 24 VAC (dual‑stage control)
- Valve Pattern : Straight-through, non-offset
- Opening Time : Rapid opening (<6 seconds)
- Closing Time : Fast closing (≤2 seconds on power failure)
- Applications : Boilers, unit heaters, duct furnaces, makeup‑air units, rooftop heaters, ovens, incinerators, and commercial/industrial burners
- Valve Type : Two‑stage, solenoid‑operated diaphragm gas valves with pressure regulation
- Pipe Size : 1 in, 1-1/4 in, 1-1/2 in NPT
- Approvals : File MH1639, Guide YIOZ, ANSI Z21.21 Compliance Valve leak test and allowable leakage rates
- Gas Type : Natural Gas, LPG
Filters