volume converters
Rotary Mini-Max Volume Corrector
The Mini-Max® Rotary Corrector is a fully featured Mini-Max electronic gas volume corrector specially adapted for direct mounting on to various rotary meters. It uses a sensor to collect input volume pulses from the sensor well of the rotary meter.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
- Small, sturdy case and integral design (instrument drive not required)
- High-performance, low-power microprocessor
- Extended battery life and high audit trail memory capacity (40 days of daily or hourly)
- FLASH memory
- Field programmable firmware updates
- Two Form-A outputs for volume and one for alarms
- Software selectable pulse widths for volume pulses
- Serial port (CMOS) with automatic baud rate settings
- High-speed data transfer (up to 38.4 kbaud)
- Onboard surge protection for serial and pulse data
Processing & Performance Metrics
- Accuracy
- Computation: ±0.3% of Corrected Volume, Pressure Transducer: ±0.4% of Full Scale, Temperature Sensor: ±1.0 deg F (±0.56 deg C), Combined: ±0.5% of Full Scale
Functional & Control Features
- Redundant Electronic Index
- Yes (REI for uncorrected volume backup)
- Integrated Sensors
- Volume, Gas Pressure, Gas Temperature
Electrical Specifications
- Power Supply
- 3.8 to 6 VDC
- Input Voltage
- +3.8 to +6 VDC
Applications & Compatibility
- Mounting
- Integral
I/O Capabilities
- Compatible Meter Types
- Dresser LMMA and B3, Romet RM1000-RM38,000, Elster American Meter B and C-Body Rotary Meters
Environmental Conditions
- Battery Life
- 4 years (with (4) D-cell alkaline batteries under normal conditions)
- Ambient Humidity
- 0 to 100% RH (Non-Condensing)
Standards & Certifications
- Approvals
- Class 1, Division 1, Group D
- Class 1, Division 2, Group D
- Class 1, Zone 0, Group IIA
- Class 1, Zone 2, Group IIA
Others
- Ambient Temperature Range
- -40 to 160 deg F
- -40 to 70 deg C
Processing & Performance Metrics
- Accuracy
- Computation: ±0.3% of Corrected Volume, Pressure Transducer: ±0.4% of Full Scale, Temperature Sensor: ±1.0 deg F (±0.56 deg C), Combined: ±0.5% of Full Scale
Functional & Control Features
- Redundant Electronic Index
- Yes (REI for uncorrected volume backup)
- Integrated Sensors
- Volume, Gas Pressure, Gas Temperature
Electrical Specifications
- Power Supply
- 3.8 to 6 VDC
- Input Voltage
- +3.8 to +6 VDC
Applications & Compatibility
- Mounting
- Integral
I/O Capabilities
- Compatible Meter Types
- Dresser LMMA and B3, Romet RM1000-RM38,000, Elster American Meter B and C-Body Rotary Meters
Environmental Conditions
- Battery Life
- 4 years (with (4) D-cell alkaline batteries under normal conditions)
- Ambient Humidity
- 0 to 100% RH (Non-Condensing)
Standards & Certifications
- Approvals
- Class 1, Division 1, Group D
- Class 1, Division 2, Group D
- Class 1, Zone 0, Group IIA
- Class 1, Zone 2, Group IIA
Others
- Ambient Temperature Range
- -40 to 160 deg F
- -40 to 70 deg C
- Ambient Temperature Range : -40 to 160 deg F|-40 to 70 deg C
- Accuracy : Computation: ±0.3% of Corrected Volume, Pressure Transducer: ±0.4% of Full Scale, Temperature Sensor: ±1.0 deg F (±0.56 deg C), Combined: ±0.5% of Full Scale
- Redundant Electronic Index : Yes (REI for uncorrected volume backup)
- Power Supply : 3.8 to 6 VDC
- Mounting : Integral
- Integrated Sensors : Volume, Gas Pressure, Gas Temperature
- Input Voltage : +3.8 to +6 VDC
- Compatible Meter Types : Dresser LMMA and B3, Romet RM1000-RM38,000, Elster American Meter B and C-Body Rotary Meters
- Battery Life : 4 years (with (4) D-cell alkaline batteries under normal conditions)
- Approvals : Class 1, Division 1, Group D|Class 1, Division 2, Group D|Class 1, Zone 0, Group IIA|Class 1, Zone 2, Group IIA
- Ambient Humidity : 0 to 100% RH (Non-Condensing)