/content/process/us/en/search.html

flame detectors

UV sensor

UV sensors for monitoring gas burners in intermittent operation in conjunction with flame detectors or automatic burner control units, EU certified in conjunction with Kromschröder automatic burner control units.

Overview
UV sensors for monitoring gas burners in intermittent operation in conjunction with flame detectors or automatic burner control units, EU certified in conjunction with Kromschröder automatic burner control units.

More Information:
Specifications

Environmental Conditions

  • Ambient Temperature Range
    • -40 to +80 deg C (-40 to +176 deg F)
  • Enclosure Rating
    • UVS 5 (IP40/IP54 (NEMA 3)), UVS 10 (IP65)

Ignition, Flame & Supervision Specifications

  • UV Tube Lifetime
    • Approximately 10,000 operating hours
  • Distance to Flame
    • UVS 5 (Max. 400 mm (16 in)), UVS 10 (300-400 mm (12-16 in); with lens: 600-1200 mm (23-47 in))

Storage/Transport Temperatures

  • Storage Temperature Range
    • -40 to +80 deg C (-40 to +176 deg F)

Inputs, Outputs & Signal Interfaces

  • Signal Output
    • DC signal, min. 1 μA

Electrical Specifications

  • Operating Voltage Range
    • 220/240 VAC (supplied by burner control unit)

Installation & Mounting Specifications

  • Mounting Options
    • UVS 5 (Bracket attached to burner), UVS 10 (Adapter with quartz glass heat guard on 1/2 in viewing tube)

Overview

  • Models
    • UVS 5, UVS 10

Measurement & Sensing Characteristics

  • Detection Method
    • Max sensitivity: 210 nm ±10 nm
    • UV tube R16388, spectral range: 185 to 280 nm

Air & Combustion Air Specifications

  • Cooling/Purge Air Option
    • UVS 5 (Not specified), UVS 10 (Yes, via cooling air adapter and nozzle options)

Dimensions & Size Specifications

  • Cable Gland Size
    • M20 for 7 to 13 mm cable diameter

Standards & Certifications

  • Approvals
    • CE Certified, Eurasian Customs Union, REACH Regulation No. 1907/2006, China RoHS

Environmental Conditions

  • Ambient Temperature Range
    • -40 to +80 deg C (-40 to +176 deg F)
  • Enclosure Rating
    • UVS 5 (IP40/IP54 (NEMA 3)), UVS 10 (IP65)

Ignition, Flame & Supervision Specifications

  • UV Tube Lifetime
    • Approximately 10,000 operating hours
  • Distance to Flame
    • UVS 5 (Max. 400 mm (16 in)), UVS 10 (300-400 mm (12-16 in); with lens: 600-1200 mm (23-47 in))

Storage/Transport Temperatures

  • Storage Temperature Range
    • -40 to +80 deg C (-40 to +176 deg F)

Inputs, Outputs & Signal Interfaces

  • Signal Output
    • DC signal, min. 1 μA

Electrical Specifications

  • Operating Voltage Range
    • 220/240 VAC (supplied by burner control unit)

Installation & Mounting Specifications

  • Mounting Options
    • UVS 5 (Bracket attached to burner), UVS 10 (Adapter with quartz glass heat guard on 1/2 in viewing tube)

Overview

  • Models
    • UVS 5, UVS 10

Measurement & Sensing Characteristics

  • Detection Method
    • Max sensitivity: 210 nm ±10 nm
    • UV tube R16388, spectral range: 185 to 280 nm

Air & Combustion Air Specifications

  • Cooling/Purge Air Option
    • UVS 5 (Not specified), UVS 10 (Yes, via cooling air adapter and nozzle options)

Dimensions & Size Specifications

  • Cable Gland Size
    • M20 for 7 to 13 mm cable diameter

Standards & Certifications

  • Approvals
    • CE Certified, Eurasian Customs Union, REACH Regulation No. 1907/2006, China RoHS
  • Ambient Temperature Range : -40 to +80 deg C (-40 to +176 deg F)
  • UV Tube Lifetime : Approximately 10,000 operating hours
  • Storage Temperature Range : -40 to +80 deg C (-40 to +176 deg F)
  • Signal Output : DC signal, min. 1 μA
  • Operating Voltage Range : 220/240 VAC (supplied by burner control unit)
  • Mounting Options : UVS 5 (Bracket attached to burner), UVS 10 (Adapter with quartz glass heat guard on 1/2 in viewing tube)
  • Models : UVS 5, UVS 10
  • Enclosure Rating : UVS 5 (IP40/IP54 (NEMA 3)), UVS 10 (IP65)
  • Distance to Flame : UVS 5 (Max. 400 mm (16 in)), UVS 10 (300-400 mm (12-16 in); with lens: 600-1200 mm (23-47 in))
  • Detection Method : Max sensitivity: 210 nm ±10 nm|UV tube R16388, spectral range: 185 to 280 nm
  • Cooling/Purge Air Option : UVS 5 (Not specified), UVS 10 (Yes, via cooling air adapter and nozzle options)
  • Cable Gland Size : M20 for 7 to 13 mm cable diameter
  • Approvals : CE Certified, Eurasian Customs Union, REACH Regulation No. 1907/2006, China RoHS
Name
Description
File Size
Date
Size
No support documents tagged to this product
An error occurred . Please try after sometime
Category@category|Type@type

Filters

Product Number
Part Number
Description
Leaf Category
Thumbnail
Add to list
KS74927869
Assembly Set f.UVS BR 80 L535 R1/2
KS74927869
Assembly Set f.UVS BR 80 L535 R1/2
KS74960611
LINSE MIT DICHTUNG (UVS10)
KS74960611
LINSE MIT DICHTUNG (UVS10)
KS74960612
QUARZGLASSCHEIBE MIT DICHTUNG (UVS10)
KS74960612
QUARZGLASSCHEIBE MIT DICHTUNG (UVS10)
KS74960615
ADAPTER UVS1 MIT QUARZGLAS
KS74960615
ADAPTER UVS1 MIT QUARZGLAS