Features & Benefits:
- Exit velocities up to 275 ft/s (190 miles/h) to promote workload heat penetration and better furnace temperature uniformity
- Operate on-ratio, with excess fuel or with excess air to meet the specific demands of your combustion process needs
- Burns most clean, low pressure gaseous fuels or light oil
- Turndown capability up to 48:1
- Maximum application flexibility with 7 different sizes and maximum capacities ranging from 0.38 MBtu/h up to 8.4 MBtu/h
- Lower fuel consumption using preheated combustion air (up to 800 °F)
- Refractory block for chamber temperatures up to 3000 °F
- Removable backplate, providing access for easy inspection and/or maintenance
- KINEMAX® burners can be used with oxygen enriched combustion air
Standards & Certifications
- Approvals
- Eurasian Customs Union (Compliant), Honeywell MAXON Standards (Applies to all models), WEEE Directive Disposal compliance
Applications & Compatibility
- Typical Applications
- High‑temperature furnaces such as oxidizers, forge furnaces, annealing furnaces, melting furnaces, lehrs, kilns, ceramic furnaces; suitable where good temperature uniformity without flame impingement is required
Performance, Flow & Capacity
- Turndown Ratio
- Up to 48:1
Dimensions & Size Specifications
- Sizes
- Series G sizes 1.5, 2, 3, 4, 6
Installation & Mounting Specifications
- Mounting Options
- Refractory block, carbon/stainless steel sleeve, flange options
Maximum/Minimum Temperature Limits
- Maximum Furnace Temperature
- Up to 3000 deg F (1650 deg C) with special refractory
Combustion/Furnace/Chamber Temperatures
- Maximum Combustion Air Temperature
- Up to 800 deg F (425 deg C)
Material Specifications
- Material
- Housing: gray/ductile iron; Block: castable refractory; Sleeve: AISi 310
Electrical Specifications
- Maintenance Interval
- Annual inspection recommended
Ignition, Flame & Supervision Specifications
- Ignition Type
- Direct Spark Ignition with integrated raw‑gas pilot (interrupted pilot recommended)
- Flame Velocity
- Up to 275 ft/s (85 m/s)
- Flame Supervision
- UV Scanner standard; flame rod option available on sizes 1.5 to 4
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Propane, Butane, Hydrogen
Burner/Flame‑Related Lengths
- Flame Length
- 4 to 48 in (100 to 1200 mm) depending on size and fuel
Air & Combustion Air Specifications
- Excess Air Capability
- Up to 4700% depending on size
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Gas and air are mixed in a cast refractory burner block tunnel (nozzle‑mixing)
Processing & Performance Metrics
- Capacity Range
- 0.38 to 8.0 MBtu/h (110 to 2348 kW)
Overview
- Burner Type
- Nozzle‑mixing, medium‑velocity industrial gas burner
Product Design & Configuration
- Burner Series
- KINEMAX® Series G
Standards & Certifications
- Approvals
- Eurasian Customs Union (Compliant), Honeywell MAXON Standards (Applies to all models), WEEE Directive Disposal compliance
Applications & Compatibility
- Typical Applications
- High‑temperature furnaces such as oxidizers, forge furnaces, annealing furnaces, melting furnaces, lehrs, kilns, ceramic furnaces; suitable where good temperature uniformity without flame impingement is required
Performance, Flow & Capacity
- Turndown Ratio
- Up to 48:1
Dimensions & Size Specifications
- Sizes
- Series G sizes 1.5, 2, 3, 4, 6
Installation & Mounting Specifications
- Mounting Options
- Refractory block, carbon/stainless steel sleeve, flange options
Maximum/Minimum Temperature Limits
- Maximum Furnace Temperature
- Up to 3000 deg F (1650 deg C) with special refractory
Combustion/Furnace/Chamber Temperatures
- Maximum Combustion Air Temperature
- Up to 800 deg F (425 deg C)
Material Specifications
- Material
- Housing: gray/ductile iron; Block: castable refractory; Sleeve: AISi 310
Electrical Specifications
- Maintenance Interval
- Annual inspection recommended
Ignition, Flame & Supervision Specifications
- Ignition Type
- Direct Spark Ignition with integrated raw‑gas pilot (interrupted pilot recommended)
- Flame Velocity
- Up to 275 ft/s (85 m/s)
- Flame Supervision
- UV Scanner standard; flame rod option available on sizes 1.5 to 4
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Propane, Butane, Hydrogen
Burner/Flame‑Related Lengths
- Flame Length
- 4 to 48 in (100 to 1200 mm) depending on size and fuel
Air & Combustion Air Specifications
- Excess Air Capability
- Up to 4700% depending on size
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Gas and air are mixed in a cast refractory burner block tunnel (nozzle‑mixing)
Processing & Performance Metrics
- Capacity Range
- 0.38 to 8.0 MBtu/h (110 to 2348 kW)
Overview
- Burner Type
- Nozzle‑mixing, medium‑velocity industrial gas burner
Product Design & Configuration
- Burner Series
- KINEMAX® Series G
- Approvals : Eurasian Customs Union (Compliant), Honeywell MAXON Standards (Applies to all models), WEEE Directive Disposal compliance
- Typical Applications : High‑temperature furnaces such as oxidizers, forge furnaces, annealing furnaces, melting furnaces, lehrs, kilns, ceramic furnaces; suitable where good temperature uniformity without flame impingement is required
- Turndown Ratio : Up to 48:1
- Sizes : Series G sizes 1.5, 2, 3, 4, 6
- Mounting Options : Refractory block, carbon/stainless steel sleeve, flange options
- Maximum Furnace Temperature : Up to 3000 deg F (1650 deg C) with special refractory
- Maximum Combustion Air Temperature : Up to 800 deg F (425 deg C)
- Material : Housing: gray/ductile iron; Block: castable refractory; Sleeve: AISi 310
- Maintenance Interval : Annual inspection recommended
- Ignition Type : Direct Spark Ignition with integrated raw‑gas pilot (interrupted pilot recommended)
- Fuel Type : Natural Gas, Propane, Butane, Hydrogen
- Flame Velocity : Up to 275 ft/s (85 m/s)
- Flame Supervision : UV Scanner standard; flame rod option available on sizes 1.5 to 4
- Flame Length : 4 to 48 in (100 to 1200 mm) depending on size and fuel
- Excess Air Capability : Up to 4700% depending on size
- Combustion Principle : Gas and air are mixed in a cast refractory burner block tunnel (nozzle‑mixing)
- Capacity Range : 0.38 to 8.0 MBtu/h (110 to 2348 kW)
- Burner Type : Nozzle‑mixing, medium‑velocity industrial gas burner
- Burner Series : KINEMAX® Series G