OXY-THERM LE Natural Gas Burners

Low NOx, Oxy-Fuel burners offering easy installation, easy switch from gas to oil, and a patented oxygen staging design

Overview
OXY-THERM® LE Natural Gas Burners provide the lowest NOx levels of any industrial oxygen/fuel burner, regardless of oxygen purity. NOx levels are up to 70% lower than conventional oxy-gas burners and up to 50% lower than conventional oxy-oil burners. OXY-THERM® LE Industrial Burners have substantially improved product quality worldwide while reducing fuel usage and emissions produced per ton of product.

Features & Benefits:
  • Extremely low NOx levels with patented oxygen staging design
  • Burns any gaseous fuel, including fuels that may be unstable using air for combustion
  • Fuel oil capability ranges from light to heavy fuel oils
  • Quickly convert between gas and oil service by changing the burner nozzle
  • Patented design eliminates flame lofting providing cooler furnace crowns
  • Designed for easy installation and service. OXY-THERM® LE Burner nozzles can be removed during furnace operation, eliminating costly downtimes
  • Dramatically increase available heat by producing higher flame temperatures from burning fuels with oxygen
More Information:
Specifications

Applications & Compatibility

  • Applications
    • Glass Furnaces, Day Tanks, Incinerators, Metal Melting Furnaces, Reheat Furnaces, Kilns; High-Temp Applications

Performance, Flow & Capacity

  • Turndown Ratio
    • 5:1 (gas), 4-5:1 (oil)

Operating/Process Temperature Ranges

  • Process Temperature Range
    • Up to 3200 deg F (1760 deg C) with standard blocks

Combustion, Mixing & Fuel Dynamics

  • Oxygen Staging
    • Optimizes heat transfer and flame volume
    • Patented oxygen staging to reduce Nox

Fuel, Gas & Media Specifications

  • Oil Capability
    • Light and heavy fuel oils (via nozzle change)
  • Fuel Type
    • Primary - Natural Gas, Alternate - Propane; up to 20% Hydrogen/80% fuel blend

Material Specifications

  • Nozzle Material
    • 440F Stainless Steel
  • Burner Material
    • Bronze casting SAE 622

Processing & Performance Metrics

  • NOx Emissions
    • Extremely low NOx using patented oxygen staging
  • Conversion Capability
    • Nozzles can be removed during operation; quick gas to oil conversion by changing the burner nozzle
  • Capacity Range
    • Gas - Series 600: 0.2-2.7 MBTU/h; Series 900: 1.5-11 MBTU/h; Series 1200: 5-13 MBTU/h (up to 15 MBTU/h possible)
    • Oil - 3.1-19.9 MBTU/h (sizes 70-400)

Installation & Mounting Specifications

  • Mounting Options
    • Do not install down-fired; support piping; use flexible connectors to reduce stress

Overview

  • Models
    • LE 600, LE 900, LE 1200
  • Burner Type
    • Oxygen‑fuel, low‑emissions burner

Dimensions & Size Specifications

  • Flame Size
    • Gas - Diameter: 18 in (S600), 30 in (S900), 36 in (S1200); length per MBTU/h: 2.2-2.0 ft (S600), 2.0-1.6 ft (S900), 2.0-1.3 ft (S1200)
    • Oil - Diameter 18-36 in; length 6-20 ft at max output (size-dependent)

Ignition, Flame & Supervision Specifications

  • Cooling Requirements
    • Provide clean, dry air or oxygen for cooling when burner is in a hot atmosphere and not firing

Applications & Compatibility

  • Applications
    • Glass Furnaces, Day Tanks, Incinerators, Metal Melting Furnaces, Reheat Furnaces, Kilns; High-Temp Applications

Performance, Flow & Capacity

  • Turndown Ratio
    • 5:1 (gas), 4-5:1 (oil)

Operating/Process Temperature Ranges

  • Process Temperature Range
    • Up to 3200 deg F (1760 deg C) with standard blocks

Combustion, Mixing & Fuel Dynamics

  • Oxygen Staging
    • Optimizes heat transfer and flame volume
    • Patented oxygen staging to reduce Nox

Fuel, Gas & Media Specifications

  • Oil Capability
    • Light and heavy fuel oils (via nozzle change)
  • Fuel Type
    • Primary - Natural Gas, Alternate - Propane; up to 20% Hydrogen/80% fuel blend

Material Specifications

  • Nozzle Material
    • 440F Stainless Steel
  • Burner Material
    • Bronze casting SAE 622

Processing & Performance Metrics

  • NOx Emissions
    • Extremely low NOx using patented oxygen staging
  • Conversion Capability
    • Nozzles can be removed during operation; quick gas to oil conversion by changing the burner nozzle
  • Capacity Range
    • Gas - Series 600: 0.2-2.7 MBTU/h; Series 900: 1.5-11 MBTU/h; Series 1200: 5-13 MBTU/h (up to 15 MBTU/h possible)
    • Oil - 3.1-19.9 MBTU/h (sizes 70-400)

Installation & Mounting Specifications

  • Mounting Options
    • Do not install down-fired; support piping; use flexible connectors to reduce stress

Overview

  • Models
    • LE 600, LE 900, LE 1200
  • Burner Type
    • Oxygen‑fuel, low‑emissions burner

Dimensions & Size Specifications

  • Flame Size
    • Gas - Diameter: 18 in (S600), 30 in (S900), 36 in (S1200); length per MBTU/h: 2.2-2.0 ft (S600), 2.0-1.6 ft (S900), 2.0-1.3 ft (S1200)
    • Oil - Diameter 18-36 in; length 6-20 ft at max output (size-dependent)

Ignition, Flame & Supervision Specifications

  • Cooling Requirements
    • Provide clean, dry air or oxygen for cooling when burner is in a hot atmosphere and not firing
  • Applications : Glass Furnaces, Day Tanks, Incinerators, Metal Melting Furnaces, Reheat Furnaces, Kilns; High-Temp Applications
  • Turndown Ratio : 5:1 (gas), 4-5:1 (oil)
  • Process Temperature Range : Up to 3200 deg F (1760 deg C) with standard blocks
  • Oxygen Staging : Optimizes heat transfer and flame volume|Patented oxygen staging to reduce Nox
  • Oil Capability : Light and heavy fuel oils (via nozzle change)
  • Nozzle Material : 440F Stainless Steel
  • NOx Emissions : Extremely low NOx using patented oxygen staging
  • Mounting Options : Do not install down-fired; support piping; use flexible connectors to reduce stress
  • Models : LE 600, LE 900, LE 1200
  • Fuel Type : Primary - Natural Gas, Alternate - Propane; up to 20% Hydrogen/80% fuel blend
  • Flame Size : Gas - Diameter: 18 in (S600), 30 in (S900), 36 in (S1200); length per MBTU/h: 2.2-2.0 ft (S600), 2.0-1.6 ft (S900), 2.0-1.3 ft (S1200)|Oil - Diameter 18-36 in; length 6-20 ft at max output (size-dependent)
  • Cooling Requirements : Provide clean, dry air or oxygen for cooling when burner is in a hot atmosphere and not firing
  • Conversion Capability : Nozzles can be removed during operation; quick gas to oil conversion by changing the burner nozzle
  • Capacity Range : Gas - Series 600: 0.2-2.7 MBTU/h; Series 900: 1.5-11 MBTU/h; Series 1200: 5-13 MBTU/h (up to 15 MBTU/h possible)|Oil - 3.1-19.9 MBTU/h (sizes 70-400)
  • Burner Type : Oxygen‑fuel, low‑emissions burner
  • Burner Material : Bronze casting SAE 622
Others
Name
Description
File Size
Date
Size
Insulating Pad Installation Manual
application/pdf 72.77 KB
3/6/1997
72.77 KB
Name
Description
File Size
Date
Size
Insulating Pad Installation Manual
application/pdf 72.77 KB
3/6/1997
72.77 KB
Name
Description
File Size
Date
Size
Insulating Pad Installation Manual
72.77 KB
3/6/1997
Name
Description
File Size
Date
Size
No support documents tagged to this product
An error occurred . Please try after sometime
Category@category|Type@type

Filters

Product Number
Part Number
Description
Leaf Category
Thumbnail
Add to list
1034283
600 OXY BRNR BLCK FRM
1034283
600 OXY BRNR BLCK FRM
1035854
70LPH 907 OIL TB ASY W/MOD+
1035854
70LPH 907 OIL TB ASY W/MOD+
1039706
900 OXY BRNR BLCK FRM
1039706
900 OXY BRNR BLCK FRM
1060205
900, 1200 BLNK PLT
1060205
900, 1200 BLNK PLT
1062199
SERV PLT
1062199
SERV PLT
1066594
600 OT LE BLNK PLT
1066594
600 OT LE BLNK PLT
1112127
607 OXY-THERM LE EX OIL BRNR+
1112127
607 OXY-THERM LE EX OIL BRNR+
1112128
907 OXY-THERM LE EX OIL BRNR+
1112128
907 OXY-THERM LE EX OIL BRNR+
1112129
910 OXY-THERM LE EX OIL BRNR+
1112129
910 OXY-THERM LE EX OIL BRNR+
1112130
915 OXY-THERM LE EX OIL BRNR+
1112130
915 OXY-THERM LE EX OIL BRNR+